If vacon 10 is disconnected from the mains while the motor is running, vacon 20 will remain live if the motor is fed by the process. The earth leakage current of vacon 20 frequency converters exceeds 3. It is built for professionals who know what they need and appreciate a convenient and easy purchasing channel. Test the vfd without a motor to possibly isolate a problem vhz. Transfer parameter data with a pda via the vacon x4s frontfacing infrared port. The store comprises of thousands of controls, industrial automation products, ac drives, spare parts and accessories and serves customers worldwide. This is a recommended solution for pumps, conveyors, and packaging, processing and washing machines. Galco industrial electronics is dedicated to providing worldclass control engineering solutions through the integration of high performance products such as fanuc fa america cncs, abb drives, control techniques, yaskawa and eaton automation. For the love of physics walter lewin may 16, 2011 duration. According to standard en6180051, a reinforced protective ground connection must be ensured.
The vacon x4 and x5 ac drives are designed for real world that is not gentle or forgiving to electronic products. Variable flow venturi vacuum pumps vdf series vaccon. Vacon is not responsible for any additional costs and expenses caused by the dismantling, installation or commissioning of a repaired or replaced product, travelling, accommodation, daily allowances or time used for travelling by the authorized service personnel. We strongly recommend using a certified electrician to set up your vfds. The manual has the same structure than the menu of the drive chapters 1 and 48. If the x4 series ac drive fails for any reason, excluding physical a buse or repeated failure, within. Manual vacon nxp system drive hardware manual vacon nx inverters fi9 14 user manual vacon nx io boards user manual vacon nx brake resistor user manual vacon nx active front end user manual vacon nxn nfe user manual vacon nx filters user manual vacon nxp ip54 control. These drives are available in the power range from 0. The builtin rs485 interface provides a costeffective and simple serialcontrol interface for the drive. Eatons application specialist, darrell ouellette guides us through the eaton svx9000, vfd setup wizard.
The touch current of vacon 100 ac drives exceeds 3. Vacon 100 and 100 flow manual inverter drive supermarket. Ethernetip is configured from panel or with vacon live. The vacon nxs or nxp ac drive is ready for operation. The company has headquarters in vaasa, finland vacon drives. In this video, we used the very popular mitsubishi d700 series vfd, showing single phase and three phase wiring instructions. The vacon 20 frequency converter has been designed for fixed. The 100 hp variable frequency drive vfd employs 3phase motor control to increase reliability and safety while simultaneously creating energy savings. This is a recommended solution for pumps, conveyors. Vfd must be able to run high efficiency pm motors permanent magnet motor controller vfd continuous current sized based on the motors nameplate maximum amps, not horsepower drive output filter is required with pm motor, dvdt filter motor leads vacon 10 is disconnected from the mains while the motor is running, vacon 20 will remain live if the motor is fed by the process. Standard, localremote, multistep speed, pid control, multipurpose or motor potentiometer. Vacon nxp quick guide vacon nxp nxc user manual vacon nxp ip00 modules inst. Vacon nx inverters user manual inverter drive supermarket.
Combining the core functionality of vacon 100 industrial, the vacon 100 flow provides specific flowcontrol functions to enhance pump and fan performance and protect pipes and equipment to ensure reliable operation. Vacon 100 ac drive is meant for fixed installations only. The enclosed vacon nxc is the compact drive that performs reliably in harsh operating conditions in, for example, the mining, oil and gas or water and wastewater industries. Varies according to size, please see manual for further details. Do not perform any measurements when the ac drive is connected to the mains. Make sure if you have a bypass function that both the vfd and bypass mode operate the motor in the same direction. The thermally managed enclosure extends drive lifetime and ensures troublefree operation. In this case, the motor functions as a generator that feeds energy to the frequency converter. A costeffective solution for small commercial applications and machine builders. The vacon 20 is available with input voltages ranging from 115 thru 600vac, and a power range up to 18. Brochure ad, danfoss drives fieldbus solutions, 804.
Dwyer instruments danfoss vlt drives vacon express supply. After disconnecting the frequency converter from the mains, wait until the fan stops and the display segments or status. Vacon 100 flow is an ac drive dedicated to improving flow control and saving energy in pumping and ventilating applications. The vacon 10 frequency converter must always be earthed with an earthing. Vacon frequency converters carry the ce mark and comply with the strictest emc radio interference directives of the eu. Vacon 20 power connections, mi4 3 380, 480v motor out brake mains motor resistor figure 3. The integrated ethernetip protocol in the vacon 100 drive must be selected when ordering the drive. A great fit for virtually any application, available brands include. The vacon 100 hvac includes a motor switch ridethrough feature that allows a maintenance switch near the fan to be opened and closed while the drive is running, without causing a trip. Chapter 1, quick startup guide how to start the work with the control panel.
Vacon frequency converters vacon cxcxlcxs frequency converters cover the power range 0,55 kw 1,5 mw, at 230400500690 v 3phase input and motor voltages. Selection guide l vacon nxp and vacon nxc ac drives l 0. From simple applications to those requiring advanced communications, vacon 5x, vacon 50x and vacon 500x offer. Vacon incorporated warrants the x4 series ac drive to be free of defects in parts or workmanship for a period of three 3 years from the date of manufacture, or two 2 years from the date of installation, whichever comes first. As maintenance engineer in a sugar factory, i have been having problem with induction motor 37kw driven by variable frequency drive vfd, type vacon nxs, this motor is running normally at 1200 rpm with draw current about 8. The profidrive operating mode can be used to enable the profile driver in the opte3e5. Your source for new surplus and factory new variable frequency drives at a great price. Vacon is a global manufacturer of variablespeed ac drives for adjustable control of electric motors, and inverters for producing energy from renewable sources. Learn the basic wiring of variable frequency drives vfd with our electrician steve quist.
Magforce highefficiency non vacon vfd settings requirements. With optional modules, vacon 20 can be connected to almost any fieldbus system based on rs485 or ethernet, including profibus dp, canopen, devicenet, profinet io, ethercat. The users manual will provide you with the necessary information about the installation, commissioning and operation of vacon nx inverters. The vacon nx frequency converter is meant for fixed installations only. Eaton svx9000, variable frequency drives startup wizard. Table of contents preface about this manual 3 startup quick guide. They have been designed to keep driving in harsh environments and are built from the ground up to survive hostile conditions and still be simple to use.
Vacon plc is not responsible if you use the ac drives against the instructions. Vacon nxp liquid cooled drives are the ultimate in spacesaving, high power density ac drives, well. If the vfd system has bypass, there will be an overload device for the bypass circuit, but if tripped, will also prevent the vfd connect to the motor. These compact pumps offer high flow rates up to 120 scfm 3400 lpm and high vacuum levels up. High tolerance to electromagnetic disturbances and a. For years, vacon has been establishing strong partnerships with leading system integrators in. Vacon nxp is a premium aircooled ac drive for use in all applications where reliability, robust performance, precision and power are required.
If the drive is not equipped with the integrated ethernetip protocol, the ethernetip menus do not appear and the protocol cannot be used. Its sleep mode is activated when there is no demand on the drive which ensures cost saving, energy efficient. It combines core functionality of vacon 100 with features that are specifically designed for flow control applications, such as multipump solutions and application selection menus. The drive automatically makes some of the necessary settings, which makes the commissioning easy. Vacon vfd variable frequency drives 3 phase power systems. Obey the commissioning instructions, see chapter 8 commissioning and additional instructions. Variable flow venturi vacuum pumps vdf series the vdf series is a unique vaccon innovation that places the vacuum port and exhaust path inline making a straightthrough venturi vacuum pump.